ACCURAD TID-X INSTRUMENTS

Bring semiconductor TID workflows into your own laboratory

AccuRad TID-X integrates X-ray irradiation, dosimetry, device bias, parameter measurement, software and delivery support for wafers, chips, power devices and electronic modules.

AccuRad TID-X semiconductor X-ray total ionizing dose system concept in a laboratory setting
Product concept visual · final model, appearance and configuration are defined in controlled technical documents

PRODUCT POSITION

More than an X-ray cabinet

Configuration starts with the device and data required, then defines irradiation, dosimetry, bias, measurement and facility conditions.

Device R&D and process studies

Compare devices, layouts, processes or bias states under controlled cumulative ionizing-dose conditions.

Reliability and quality verification

Bring dose steps, electrical or functional measurements, criteria and reporting into a repeatable internal workflow.

Shared test and research platforms

Support multiple device types and users through scalable fixtures, instruments and data workflows.

In-house laboratory capability

Coordinate equipment, methods, training and service from facility, protection and licensing boundaries.

SYSTEM ARCHITECTURE

Four coordinated modules

Final models, ranges, channels and performance claims are defined together with verifiable acceptance conditions in the technical agreement.

Irradiation and motion control

X-ray source, sample plane, positioning, shutter, control and the required safety interlocks.

Dosimetry and field mapping

Reference medium, detector, calibration, dose records and field-uniformity evaluation.

Sample, bias and measurement

Fixtures, bias channels, instrument interfaces, cabling and electrical measurement checkpoints.

Software, records and export

Test configuration, system state, dose, bias, measurements, logs and data export.

TEST WORKFLOW

From sample intake to data export

Connect sample information, test configuration, dose records, bias state, measurements and system logs in a repeatable, reviewable and extensible workflow.

Explore systems and laboratory integration
AccuRad TID-X functional architecture for the X-ray source, beam conditioning, dosimetry, DUT fixture, bias and safety interlocks
Internal functional architecture · mechanical layout, components and interfaces are defined in controlled technical documents

CONFIGURATION LOGIC

Answer six questions before selecting the system

A useful comparison goes beyond one dose-rate or power number: the sample, method, data and facility must work together.

DEVICE

What devices?

Wafers, bare die, packaged devices, board-level assemblies or electronic modules.

DECISION

What decision?

Process comparison, device screening, reliability study, product verification or research.

DOSE

What dose conditions?

Total dose, dose rate, steps, reference medium and field-uniformity expectations.

STATE

How does the DUT operate?

Static or dynamic bias, channel count, limits, timing and exception handling.

MEASUREMENT

What must be measured?

Offline or in-situ parameters, instruments, sampling cadence, data volume and criteria.

FACILITY

What facility is available?

Space, shielding, licensing, power, ventilation, network, logistics and maintenance.

DELIVERY AND SUPPORT

From configuration to continuing operation

Installation is not the finish line. Methods, acceptance records, training, maintenance and later expansion determine whether the capability remains usable.

01

Application assessment

Define devices, samples, dose, bias, measurements, throughput and expected use.

02

Configuration and agreement

Confirm the system, dosimetry, fixtures, instruments, software, interfaces and acceptance method.

03

Build and site preparation

Coordinate manufacturing with facility, protection, licensing, utilities and installation readiness.

04

Installation, acceptance and training

Complete agreed functional and performance checks and introduce operating and application methods.

05

Continuing service and expansion

Support calibration, maintenance, refresher training, fixtures, software and application work.

Licensing and safety boundary X-ray systems avoid purchasing, transporting and replacing radioisotope sources. Production, sale and use still remain subject to applicable radiation-safety licensing, protection, monitoring and personnel-management requirements.

PROJECT INTAKE

Ready to evaluate a TID-X configuration?

Share a non-sensitive device range, sample size, target dose, bias, measurement needs and expected usage so we can assess application and facility boundaries.

Submit an initial request
Request a testResponse within four business hours